Detection Target
Determination of Silicon, manganese, phosphorus, chromium, molybdenum, nickel, copper in steel
Overview
This solution conforms to the ISO 17650 Low-alloyed steel—Determination of Mn, P, Cr, Ni, Mo, Co, Cu, V, Ti, As and Sn—Inductively coupled plasma optical emission spectrometric method. This standard specifies a method for the determination of Mn, P, Cr, Ni, Mo, Co, Cu, V, Ti, As and Sn contents in low alloyed steel by inductively coupled plasma optical emission spectrometry(ICP-OES).
Apparatus
HKL-17650 ICP for Determination of metallic element content in steel
Technical Parameters
Radio-Frequency Generator
1) Operating Frequency: 27.12 MHz
2) Frequency Stability: <0.05%
3) Output Power: 800 W – 1600 W
4) Output Power Stability: ≤0.05%
5) Matching Mode: Automatic matching
Scanning Spectrometer
1) Optical Path: Czerny-Turner type
2) Focal Length: 1000 mm
3) Grating Specifications: Ion-etched holographic grating, Groove density: 3600 L/mm or 2400 L/mm, Ruled area: (80 × 110) mm
4) Reciprocal Linear Dispersion: 0.26 nm/mm
5) Resolution: ≤0.008 nm (with 3600 L/mm grating), ≤0.015 nm (with 2400 L/mm grating)
Whole Machine
1) Scanning Wavelength Range: 195 nm to 500 nm (with 3600 L/mm grating), 195 nm to 800 nm (with 2400 L/mm grating)
2) Repeatability: RSD ≤1.5%
3) Stability: RSD ≤2.0%
Assessment of Detectable Elements
Sample | Elements Measured | Apparatus | Sample Preparation Overview | Remarks |
Metal Material | Si, Mn, P, Cr, Mo, Ni, Cu | HKL-17650 ICP for Determination of metallic element content in steel | Weigh approximately 0.2-0.5g sample, add a certain amount of nitric acid, heat at low temperature. After the solution becomes clear, cool to room temperature and transfer to a 100ml volumetric flask. Dilute to volume with water and mix well. | Blank and parallel sample tests are required for accurate determination of Si content. |
Configuration
Main Unit and Essential Accessories | ||||
Serial | Name | Specification | Number | Remarks |
1 | Inductively Coupled Plasma Spectrometer | HKL-17650 ICP for Determination of metallic element content in steel | 1 set | |
2 | Automatic Temperature-controlled Detector Cooling | 1 set | ||
3 | Voltage Regulated Power Supply | 1 set | ||
Optional | ||||
Serial | Name | Specification | Number | Remarks |
1 | Computer Main Unit | 1 set | ||
2 | Computer Monitor | 1 set | ||
3 | Printer | 1 set | ||
Sample Processing Equipment and Consumables | ||||
Serial | Name | Specification | Number | Remarks |
1 | Digital Temperature-controlled Hot Plate | EG-35B | 1 set | |
2 | Analytical balance (0.1mg precision) | BS224S | 1 set | |
3 | Ultra-Pure Water Machine | EPED-40T | 1 set | |
4 | Disposable rubber gloves | M-size | ||
5 | Activated carbon mask | |||
6 | 3ml Pasteur pipettes | 3ml | ||
7 | 100ml glass beaker | 100ml | ||
8 | 100ml glass volumetric flask | 100ml | ||
9 | 5ml Micropipette | 0.5ml-5ml | 1 pc | |
10 | 1ml Micropipette | 100ul-1000ul | 1 pc | |
11 | 100μl Micropipette | 10ul-100ul | 1 pc | |
Reagents | ||||
Serial | Name | Specification | Number | Remarks |
1 | Hydrochloric acid | Guaranteed Reagent | ||
2 | Nitric acid | Guaranteed Reagent | ||
3 | Hydrogen peroxide | Guaranteed Reagent | ||
4 | Elemental standard reference materials | 1000ug/ml | ||