ISO 17650 Determination of metallic element content in steel by ICP

2026-02-03

Detection Target

Determination of Silicon, manganese, phosphorus, chromium, molybdenum, nickel, copper in steel

Overview

This solution conforms to the ISO 17650 Low-alloyed steel—Determination of Mn, P, Cr, Ni, Mo, Co, Cu, V, Ti, As and Sn—Inductively coupled plasma optical emission spectrometric method. This standard specifies a method for the determination of Mn, P, Cr, Ni, Mo, Co, Cu, V, Ti, As and Sn contents in low alloyed steel by inductively coupled plasma optical emission spectrometry(ICP-OES).

Apparatus

HKL-17650 ICP for Determination of metallic element content in steel

Technical Parameters

  1. Radio-Frequency Generator

    1) Operating Frequency: 27.12 MHz

    2) Frequency Stability: <0.05%

    3) Output Power: 800 W – 1600 W

    4) Output Power Stability: ≤0.05%

    5) Matching Mode: Automatic matching

  2. Scanning Spectrometer

    1) Optical Path: Czerny-Turner type

    2) Focal Length: 1000 mm

    3) Grating Specifications: Ion-etched holographic grating, Groove density: 3600 L/mm or 2400 L/mm, Ruled area: (80 × 110) mm

    4) Reciprocal Linear Dispersion: 0.26 nm/mm

    5) Resolution: ≤0.008 nm (with 3600 L/mm grating), ≤0.015 nm (with 2400 L/mm grating)

  3. Whole Machine

    1) Scanning Wavelength Range: 195 nm to 500 nm (with 3600 L/mm grating), 195 nm to 800 nm (with 2400 L/mm grating)

    2) Repeatability: RSD ≤1.5%

    3) Stability: RSD ≤2.0%

Assessment of Detectable Elements


Sample

Elements Measured

Apparatus

Sample Preparation Overview

Remarks

Metal Material

Si, Mn, P, Cr, Mo, Ni, Cu

HKL-17650 ICP for Determination of metallic element content in steel

Weigh approximately 0.2-0.5g sample, add a certain amount of nitric acid, heat at low temperature. After the solution becomes clear, cool to room temperature and transfer to a 100ml volumetric flask. Dilute to volume with water and mix well.

Blank and parallel sample tests are required for accurate determination of Si content.


Configuration


Main Unit and Essential Accessories

Serial

Name

Specification

Number

Remarks

1

Inductively Coupled Plasma Spectrometer

HKL-17650 ICP for Determination of metallic element content in steel

1 set


2

Automatic Temperature-controlled Detector Cooling


1 set


3

Voltage Regulated Power Supply


1 set


Optional

Serial

Name

Specification

Number

Remarks

1

Computer Main Unit


1 set


2

Computer Monitor


1 set


3

Printer


1 set



Sample Processing Equipment and Consumables

Serial

Name

Specification

Number

Remarks

1

Digital Temperature-controlled Hot Plate

EG-35B

1 set


2

Analytical balance (0.1mg precision)

BS224S

1 set


3

Ultra-Pure Water Machine

EPED-40T

1 set


4

Disposable rubber gloves

M-size



5

Activated carbon mask




6

3ml Pasteur pipettes

3ml



7

100ml glass beaker

100ml



8

100ml glass volumetric flask

100ml



9

5ml Micropipette

0.5ml-5ml

1 pc


10

1ml Micropipette

100ul-1000ul

1 pc


11

100μl Micropipette

10ul-100ul

1 pc



Reagents

Serial

Name

Specification

Number

Remarks

1

Hydrochloric acid

Guaranteed Reagent



2

Nitric acid

Guaranteed Reagent



3

Hydrogen peroxide

Guaranteed Reagent



4

Elemental standard reference materials

1000ug/ml