HKL-2158 Volatility and Residues in LPG Apparatus

2026-03-24

HKL-2158 Volatility and Residues in Liquefied Petroleum (LP) Gases Apparatus conforms to the ASTM D2158 Standard Test Method for Residues in Liquefied Petroleum (LP) Gases and ASTM D1837 Standard Test Method for Volatility of Liquefied Petroleum (LP) Gases. This apparatus covers the determination of extraneous materials weathering above 38°C that are present in liquefied petroleum gases. The extraneous materials will generally be dissolved in the LPG, but may have phase-separated in some instances.

Features

  1. Digital display temperature controller with easy and flexible operation. Temperature controlling precision is high.

  2. The heating output adopts solid-state relay, contactless, sparkless, noiseless and long life time.

  3. The heater adopts stainless steel material. The heating rate is fast and the operation time is long.

  4. The bath of the apparatus adopts stainless steel material, corrosion resisting and oxidation resisting. It is suitable to all kinds of mediums

  5. The apparatus adopts compressor to do composite cooling. The cooling rate is fast. big depth with good stability.

  6. Rational design with attractive appearance and friendly to the environment.

Technical Parameters

  1. Rated voltage:220V±10% 50Hz or 110V±10% 60Hz

  2. Power:2000W

  3. Temperature controlling mode: digital display

  4. Temperature of cooling bath:-55℃~30℃ ±0.1℃

  5. The temperature of bath: 38℃ ±0.1℃

  6. Sensor: Pt100

  7. Stirring mode: electrical motor stir

  8. Ambient requirements: Temperature:10~40℃; Humidity≤85%

Being able to control residue levels is very significant especially when the product is to be used in applications. If liquid feed systems are used, residues may cause deposits that are difficult to remove and residues carried over in vapor offtake systems may cause fouling of the regulating equipment. Apart from being corrosive, the residues that may remain will accumulate and contaminate the subsequent product. Water, in particular if it is alkaline, is one of the major factors that can lead to the failure of the regulating equipment and the corrosion of metals.

ASTM D2158

HKL-2158 Volatility and Residues in LPG Apparatus


About Hong Kong Laboratory Technology Limited

Since 2018, Hong Kong Laboratory Technology Limited has been a reliable partner in the instrumentation industry. We have created a strong network over the last eight years, assisting more than 500 clients by exclusively representing 50+ world-renowned brands. Leveraging our profound understanding of the industry, we offer an end-to-end supply chain service starting from Research and Development to the final production, all backed by a strict quality management system. We ensure our main instruments are developed based on the highest worldwide standards (ISO 9001, ASTM, IP) and are regularly calibrated according to ISO/IEC 17025 standards to maintain accuracy and dependability. Our dedication lies in supporting innovation and guaranteeing safety through our instruments for various sectors such as research centers, petrochemical and mining industries, healthcare institutions, and environmental bodies.

Get the latest price? We will reply as soon as possible (within 12 hours)