HKL-6304 Moisture Content Tester
Overview
HKL-6304 Moisture Content Tester conforms to the ASTM D6304 Standard Test Method for Determination of Water in Petroleum Products, Lubricating Oils, and Additives by Coulometric Karl Fischer Titration. This method uses Karl Fischer titration to determine the amount of water in a sample. A coulometric apparatus is used to generate iodine for the Karl Fischer reaction at the anode. When all the water has been titration, excess iodine is detected by an electrometric end point detector and the titration is terminated. Based on the stoichiometry of the reaction, 1 mole of iodine reacts with 1 mole of water; thus, the quantity of water is proportional to the total integrated current according to Faraday’s Law.
Features
The instrument is equipped with a color LCD screen and a user-friendly software interface, complemented by English prompts, thereby facilitating flexible and convenient human-machine interaction. In addition to features such as high detection sensitivity, ease of operation, rapid testing speed, and excellent repeatability, the instrument—in accordance with relevant standard literature—also offers functions including moisture absorption measurement, test result storage, and time display.
Multiple moisture content display modes for intuitive and convenient reading.
Automatic detection function for open-circuit faults in the electrolysis electrode.
Features automatic detection functions for open-circuit and short-circuit conditions of the measuring electrode, as well as for excessive iodine content in the electrolyte.
Stepless electronic speed adjustment for stirring.
Auto-start function—simply injects the sample to begin testing, minimizing human error.
Three sample introduction modes (volumetric, weight-based, and dilution) with automatic moisture content calculation, significantly improving testing efficiency.
Wi-Fi communication capability – Works with PC software to view real-time/historical data, generate test reports, and supports remote printing.
Flexible parameter input – Allows pre-entry or post-test input with automatic moisture content calculation.
Simultaneous multi-unit moisture display for intuitive comparison.
Automatic test data printing.
Data statistics function – Processes up to 32 test results with sorting, averaging, and outlier removal.
Timestamped data storage with 10,000-record capacity.
Time display function.
Technical Parameters
Titration Method: Microprocessor-controlled titration.
Electrolysis Current Output: 0-300mA automatically controlled.
Display System: Large-color LCD screen
Measuring Range: 10μg–100mg H2O.
Sensitivity Threshold: 0.1μg H2O.
Accuracy: ±3μg for 10μg–1mg H2O, 0.3% for >1mg H2O (excluding sampling error).
Power Consumption: <30VA.
Operating Environment: Temperature: 5°C–40°C, Humidity: <85% RH.
Dimensions (L×W×H): 385×290×280 mm.
Weight: Approx. 8 kg.
Power Supply: AC 220V ±10%, 50Hz ±2.5Hz.
FAQ
Q1: What standards does this product (HKL-6304 Moisture Content Tester) comply with?
A: HKL-6304 Moisture Content Tester conforms to the ASTM D6304 Standard Test Method for Determination of Water in Petroleum Products, Lubricating Oils, and Additives by Coulometric Karl Fischer Titration. This test method covers the direct determination of entrained water in petroleum products and hydrocarbons using automated instrumentation. This test method also covers the indirect analysis of water thermally removed from samples and swept with dry inert gas into the Karl Fischer titration cell. Mercaptan, sulfide, sulfur, and other compounds are known to interfere with this test method. This test method is intended for use with commercially available coulometric Karl Fischer reagents and for the determination of water in additives, lube oils, base oils, automatic transmission fluids, hydrocarbon solvents, and other petroleum products. By proper choice of the sample size, this test method may be used for the determination of water from mg/kg to percent level concentrations.
Q2: The working principle of HKL-6304 Moisture Content Tester?
A: This method uses Karl Fischer titration to determine the amount of water in a sample. A coulometric apparatus is used to generate iodine for the Karl Fischer reaction at the anode. When all the water has been titration, excess iodine is detected by an electrometric end point detector and the titration is terminated. Based on the stoichiometry of the reaction, 1 mole of iodine reacts with 1 mole of water; thus, the quantity of water is proportional to the total integrated current according to Faraday’s Law.
Q3: The significance and use of HKL-6304 Moisture Content Tester?
A: A knowledge of the water content is important in the manufacturing, purchase, sale, or transfer of petroleum products to help in predicting their quality and performance characteristics. The presence of moisture could lead to premature corrosion and wear, an increase in the debris load resulting in diminished lubrication and premature plugging of filters, an impedance in the effect of additives, and undesirable support of deleterious bacterial growth.
Q4: Do you provide product operation manuals or technical documentation?
A: Yes, we offer electronic versions of product manuals, quick operation guides, application cases, and standard operating procedures (SOPs). These can be accessed by logging into the download center on our official website or by contacting customer service to request them.
Q5: How do I track my order?
A: Once the goods are shipped, we will provide a waybill number/bill of lading number and a tracking link. You can track your goods in real time through the official website of the courier or logistics company, or you can contact our customer service.

About us
Hong Kong Laboratory Technology Limited has been a trusted partner in the instrumentation industry since 2018. Over the past eight years, we have built a robust ecosystem, supporting more than 500 clients through the exclusive representation of over 50 global brands. With deep industry insights, we provide a seamless supply chain service from Research and Development to final production, supported by a rigorous quality management system. Our core instruments are designed to meet global standards (ISO 9001, ASTM, IP) and calibrated to ISO/IEC 17025 standards, ensuring accuracy and reliability. We are committed to providing innovation and safety assurance for research institutions, petrochemical and mining companies, medical institutions, and environmental organizations.
Company Advantages
(1)Full-Chain Resource Integration Capability
(2)Professional Technical Service Team
(3)Rich Industry Practical Cases
(4)Reliable After-Sales Service
Service Guarantee
1. Online Training Services
If needed, we will provide online installation and debugging services, as well as comprehensive operation training. We also offer 24/7 online training support to end users throughout the year.
2. Professional After-Sales Service
Depending on the type of instrument, we can provide professional repair services. Our goal is to become the highest quality and most reliable instrument supplier in the market. We welcome your valuable feedback and suggestions to help us continuously improve our service quality.
Logistics and Shipping
Worldwide Shipping: We have extensive experience in shipping goods to Asia, Europe, the Middle East, and other regions.
Secure Packaging: Laboratory instruments are carefully packed to ensure they are properly secured and protected during transit.
International Certification
|
|
ISO 9001 Certification | ASTM Certificate |