  • 30 sets one month
1. Aluminium oxide powders are decomposed by acid pressure decomposition, acid decomposition or alkali fusion. 2. The calcium, chromium, copper, iron, magnesium, manganese, potassium, silicon, sodium, titanium, zinc and zirconium contents in the test solution are determined by an inductively coupled plasma-optical emission spectrometer (ICP-OES).

HKL-3169 ICP for Determination of impurities in aluminum oxide

Overview

HKL-3169 ICP for Determination of impurities in aluminum oxide conforms to the ISO 3169 Fine ceramics (advanced ceramics, advanced technical ceramics) — Methods for chemical analysis of impurities in aluminium oxide powders using inductively coupled plasma-optical emission spectrometry. Aluminium oxide powders are decomposed by acid pressure decomposition, acid decomposition or alkali fusion. The calcium, chromium, copper, iron, magnesium, manganese, potassium, silicon, sodium, titanium, zinc and zirconium contents in the test solution are determined by an inductively coupled plasma-optical emission spectrometer (ICP-OES).

Features

1. Multiple Safety Safeguards: This device has a complex and elaborate flame safety system with multiple investigation points. The first one is sensors that use fiber optics to continuously track the level of a flame; if a flame-out occurs, the system will instantly disconnect the power. This essential safety feature guarantees that the instrument will not be harmed if the water, gas, or power supply is interrupted.

Inductively Coupled Plasma Atomic Absorption Spectrometer

2. Ultra-High Resolution (less than or equal to 0.005 nm): Our system can typically resolve wavelengths at a level of 0.008 nm, which means that, in terms of wavelength resolving power, it is really exceptional. At this level of resolution, it is as if spectral interferences are virtually eliminated since there is very little crosstalk between adjacent peaks leading to a significant increase in accuracy and reliability of the measurement results.

3. Using our rapid-exchange sample introduction system will lead to a quicker and more accurate setup process. Leveraging patented tooling, the torch and coil can be aligned concentrically in only one second, thus eradicating the drudgery of making repeated adjustments. The brand-new fastening mechanism is a complete overhaul of the original snap-lock design and brings about a remarkable increase in both ease of installation and positioning accuracy.

ICP Analyzer

4. Original imported, high-efficiency, high-sensitivity concentric nebulizer.

element analyzer

5. Description of Major Instrument Components 

The nebulizer is sourced from GE (Australia)

The ion-etched holographic grating is sourced from Newport (USA)

The detector features a high-performance detection chamber from Hamamatsu (Japan)

Two DC motors are imported from the USA

Two vacuum capacitors are imported from the USA

The drive unit is imported from the USA

6. ICP Key Metric: RSD—Back-tested Data Following On-site Calibration Curve Generation

Inductively Coupled Plasma Atomic Absorption Spectrometer

Technical Parameters

  1. Solid-State Power Supply

    1)Circuit Type: Inductive Feedback Self-Oscillating Circuit; Coaxial Cable Output; Matched Tuning; Closed-Loop Automatic Power Control.

    2)Operating Frequency: 27.15 MHz ± 0.02%

    3)Frequency Stability: <0.05%

    4)Output Power: 800 W – 1200 W

    5)Output Power Stability: < 0.25%

    6)Electromagnetic Leakage Radiation Intensity: Electric field strength (E) < 2 V/m at a distance of 30 cm from the chassis.

  2. Argon Flowmeter and Carrier Gas Pressure

    1)Plasma Gas Flow Rate: 100–1000 L/h (1.67–16.7 L/min)

    2)Carrier Gas Regulator:0–0.4 Mpa

    3)Cooling Circulating Water: Temperature: 20–25°C, Flow Rate: 5 L/min, Pressure: 0.1 MPa

  3. Monochromator

    1)Optical Path: Czerny-Turner

    2)Focal Length: 1000 mm

    3)Grating Specifications: Ion-etched holographic grating; groove density: 2400 lines/mm

    4)Reciprocal Linear Dispersion: 0.25 nm/mm

    5)Resolution: ≤ 0.012 nm (2400 lines)

    6)Scanning Wavelength Range: 2400 lines/mm: 190–800 nm

    7)Minimum Step Size (Stepping Motor Drive): 0.0005 nm

    8)Exit Slit: 14 μm

    9) Entrance Slit: 8 μm

  4. Photoelectric Converter

    1)Photomultiplier Tube (PMT): R293 or R298

    2)Photomultiplier Tube Negative High Voltage: 0–999 V; Stability <0.08%

  5. Whole Machine

    1)Wavelength Scanning Range: 195–800 nm (2400 lines/mm grating)

    2)Repeatability (RSD): ≤1.6%

    3)Stability (RSD):≤1.87%

Detection Limit


Element

Wavelength

Detection Limit

Element

Wavelength

Detection Limit

Tm

313.126

≤2.9

Ba

455.403

≤1.0

Mg

279.553

1.1

Sn

242.949

19.5

Pr

414.311

4.8

Zr

343.823

4.5

Fe

239.562

≤3.0

Sr

407.771

≤1.0

Eu

381.967

≤1.0

Au

242.795

4.6

Gd

342.247

≤10.0

Pt

265.945

4.6

Ca

393.366

0.8

Pd

340.458

4.5

Er

337.271

≤3.0

Ru

240.272

≤5.0

Zn

213.856

2.9

As

228.812

≤13

Lu

261.541

2.5

Sb

206.833

≤12

Y

371.030

0.9

Bi

223.061

8

Sc

335.373

0.7

Hg

253.652

13

Ta

226.230

4.8

Pb

220.353

14

Nb

313.340

4.7

Ga

294.364

≤10

Mn

257.610

≤3.0

Se

203.985

9

Nd

401.225

≤5.05

Ag

328.068

2.5

B

249.773

≤10.1

Te

214.281

8..5

Ti

334.941

2.7

K

766.490

55

Si

251.611

≤10.0

Tl

276.787

28

Ni

232.003

≤5.0

Re

227.525

≤5.0

Cd

226.502

2.8

Ge

209.426

≤14.5

Mo

281.615

4.9

Cu

324.754

2.85

V

310.230

4.9

Li

670.784

≤3

Be

313.041

≤1.0

Na

588.995

19


FAQ

  1. Q1: Which standard does this product (HKL-3169 ICP for Determination of impurities in aluminum oxide) comply with?

    A: HKL-3169 ICP for Determination of impurities in aluminum oxide conforms to the ISO 3169 Fine ceramics (advanced ceramics, advanced technical ceramics) — Methods for chemical analysis of impurities in aluminium oxide powders using inductively coupled plasma-optical emission spectrometry. Aluminium oxide powders are decomposed by acid pressure decomposition, acid decomposition or alkali fusion. The calcium, chromium, copper, iron, magnesium, manganese, potassium, silicon, sodium, titanium, zinc and zirconium contents in the test solution are determined by an inductively coupled plasma-optical emission spectrometer (ICP-OES).

  2. Q2: What is the applicable scope of HKL-3169 ICP for Determination of impurities in aluminum oxide?

    A: This document specifies methods for the chemical analysis of impurities present in aluminium oxide powders used as a raw material for fine ceramics.

  3. Q3: Do you provide online training services?

    A: We provide comprehensive remote support for system setup and training. In addition to installation services, we ensure your team's success through a full range of online training—available 24 hours a day, 365 days a year.

  4. Q4: How do I track my order?

    A: After the shipment is dispatched, we will provide the tracking number / bill of lading number and a tracking link. You can track your shipment in real-time via the courier’s or logistics company’s official website or by contacting our customer service.

  5. Q5: Do you have relevant industry certifications?

    A: Our company has passed ISO9001 quality management system certification, and our products possess necessary certifications such as CE and CPA (type approval for measuring instruments) to ensure product quality and data accuracy.

ICP Analyzer

About us

Hong Kong Laboratory Technology Limited specializes in supply chain integration and full-chain technical services for laboratory instruments. With years of industry expertise, our company operates under a stringent quality management system, complying with multiple international standards including ISO 9001, ASTM, and IP requirements. The core products not only comply with the ISO/IEC 17025 instrument calibration and testing standards, but are also widely used in research institutions, petrochemical andmining industries, medical institutions,and environmental protection departments. This high-standard quality has earned broad market and customer trust.

Company Advantages

(1)Full-Chain Resource Integration Capability

(2)Professional Technical Service Team

(3)Rich Industry Practical Cases

(4)Reliable After-Sales Service

Service Guarantee

1. Online Training Services

It is our mission to give you the best performance of your instruments. Our support team assists you with online guidance during installation and setup of your instruments. Besides, we provide your employees with full operational training courses to help them master the use of the instruments. To keep you on the right path, we provide users with online training and support services 24/7, throughout the year.

2. Professional After-Sales Service

We understand that each instrument and piece of equipment has its own set of maintenance requirements; therefore, we offer specialized maintenance services that are tailored to these specific needs. Our big dream is to be a partner that the whole industry looks up to, recognized for supplying instruments that are not only highly reliable but also of excellent quality. To achieve this, we will always count on your precious feedback to help us keep improving the quality of our service in every phase of the process.

Logistics and Shipping

Worldwide Shipping:Our team has a lot of experience in dealing with the shipment of products to Asia, Europe, Middle East, and other parts of the world.

Secure Packaging: Lab instruments are wrapped carefully so that they are well secured and protected during the trip.

International Certification

element analyzer

Inductively Coupled Plasma Atomic Absorption Spectrometer

ISO 9001 Certification

ASTM Certificate

1. Aluminium oxide powders are decomposed by acid pressure decomposition, acid decomposition or alkali fusion. 2. The calcium, chromium, copper, iron, magnesium, manganese, potassium, silicon, sodium, titanium, zinc and zirconium contents in the test solution are determined by an inductively coupled plasma-optical emission spectrometer (ICP-OES).

HKL

Hong Kong,China

deliver as soon as received payment

30 sets one month

Product Info

Related Products