• EPA Method 8440 FTIR for Total Recoverable Hydrocarbons
  • video

EPA Method 8440 FTIR for Total Recoverable Hydrocarbons

  • HKL
  • Hong Kong,China
  • deliver as soon as received payment
  • 30 sets one month
1.This standard is used for the measurement of total recoverable petroleum hydrocarbons (TRPHs) extracted with supercritical carbon dioxide from sediment, soil and sludge samples. 2. It is not applicable to the measurement of gasoline and other volatile petroleum fractions, because of evaporative losses.

HKL-8440 FTIR Spectrometer for total recoverable petroleum hydrocarbons

Overview

HKL-8440 FTIR Spectrometer for total recoverable petroleum hydrocarbons conforms to the EPA Method 8440 Total Recoverable Petroleum Hydrocarbons by Infrared Spectrophotometry. This standard is used for the measurement of total recoverable petroleum hydrocarbons (TRPHs) extracted with supercritical carbon dioxide from sediment, soil and sludge samples. It is not applicable to the measurement of gasoline and other volatile petroleum fractions, because of evaporative losses.

Soil samples are extracted with supercritical carbon dioxide. Interferences are removed with silica gel, either by shaking the extract with loose silica gel, or by passing it through a silica gel solid-phase extraction cartridge. Following infrared (IR) analysis of the extract, TRPHs were quantitatively analyzed through direct comparison with standards.

Features

  1. Highly Stable Optical System: An integrated design and one-piece molding process have been adopted for this optical platform, which facilitates precise positioning of the main components by means of only one single alignment procedure and there is no need of adjustments afterwards. This greatly improves the stability of the instrument and totally solves the issue of maintenance of traditional optical structures, which is a big problem.

  2. Advanced Electronic Architecture: The system features a latest 24-bit A/D converter with a sampling rate of 500 kHz. A highly sensitive imported infrared detector is used to acquire real-time spectral data at the highest precision and reliability. Transferring data has become much faster due to the introduction of USB 2.0 communication interface, enabling the whole sample analysis to be done in seconds.

  3. Intelligent Humidity Management System: Equipped with a sealed interferometer and continuous humidity monitoring, this spectrometer drastically lessens the reliance on the manual user interventions. A visual, color-changing indicator that is very intuitive lets you know when the desiccant needs to be changed, thus preventing one of the main risks in FTIR operation. Changing the desiccant is fast and easy, and you don't even have to take the instrument apart.

  4. Integrated Corner Reflector Technology: It uses one piece of gold-plated reflector only that has been used in both dynamic and static optical systems. It has been designed to reach maximum light throughput and highest reflectivity. Since there is no glue used, such a structure is resistant to change in the surrounding temperature and has high stability.

  5. Core components imported from the Developed countries in Europe and America; Light source, detector, beam splitter, die: All these major components are imported from the Western countries. The quality is guaranteed as those imported components are top-notch.

Technical Parameters

  1. Spectral Range: 7800–350 cm-1

  2. Resolution: better than 1.0 cm-1

  3. Signal-to-Noise Ratio: 30000:1 (Peak-to-Peak value, 4 cm-1 resolution, 1-minute background and sample scan, Test wavenumber: 2100 cm-1), RMS value: 150000:1

  4. Detector: High-sensitivity infrared detector (imported) (Advantages: High testing accuracy, excellent repeatability, easy maintenance, and durable.)

  5. Beamsplitter: Multilayer-coated potassium bromide (KBr) (imported)

  6. Scanning Speed: Microcomputer-controlled with selectable scanning speeds, continuously adjustable, automatic spectrum comparison.

  7. Light Source: Long-life, high-intensity air-cooled system (imported)

  8. Wavenumber Accuracy: 0.01 cm-1

  9. Software Workstation: Included with the instrument, approximately 200000 standard infrared spectral libraries.

  10. Noise Level: <4.3 × 10-5 A

  11. Power Supply: AC 220V, 50Hz

  12. Data Transmission Interface: High-speed USB 2.0

  13. Operating system: win7/win10

  14. Weight: 14kg

FAQ

  1. Q1: Which standards are met by a HKL-8440 FTIR Spectrometer for total recoverable petroleum hydrocarbons?

    A: HKL-8440 FTIR Spectrometer for total recoverable petroleum hydrocarbons conforms to the EPA Method 8440 Total Recoverable Petroleum Hydrocarbons by Infrared Spectrophotometry. Soil samples are extracted with supercritical carbon dioxide. Interferences are removed with silica gel, either by shaking the extract with loose silica gel, or by passing it through a silica gel solid-phase extraction cartridge. After infrared (IR) analysis of the extract, TRPHs are quantitated by direct comparison with standards.

  2. Q2: Scope of application?

    A: This instrument is used as a referee method for determining both the interstitial oxygen content in double-side polished silicon slices and the substitutional carbon concentration in single crystal silicon. It is essential for materials acceptance, fabrication process control, and research and development.

  3. Q3: What is the minimum order quantity? How long is the delivery lead time?

    A: The minimum order quantity is one unit, and delivery is approximately 20 days after advance payment.

  4. Q4: Are there discounts for bulk purchases/wholesale?

    A: Yes, we offer highly competitive tiered pricing and bulk purchase incentives for customers with volume procurement needs (such as university centralized procurement, complete laboratory setups, OEM manufacturing, and channel distributors).

  5. Q5: How is their safety ensured during transportation?

    A: We have a professional instrument packaging team that uses customized shock-absorbing foam boxes and reinforced wooden crates. We also partner with logistics providers who specialize in precision instrument transportation to ensure that the goods are delivered to you safely and without damage.

Solid Waste Analyzer

About us

In action, Hong Kong Laboratory Technology Co., Ltd., a partner specializing in laboratory instrument supply chain integration and comprehensive technical service, is a company under a quality management system that is high on quality and has lots of deep-rooted expertise in the industry. Our main products are in full compliance with the ISO/IEC 17025 standard calibration and testing requirements. With these high-standard solutions, our product and service line has been embraced widely by scientific research institutes, petrochemical enterprises, mining enterprises, healthcare facilities, and environmental protection departments. In fact, our brand has garnered a lot of trust in the market and has been highly praised by customers.

Company Advantages

(1)Full-Chain Resource Integration Capability

(2)Professional Technical Service Team

(3)Rich Industry Practical Cases

(4)Reliable After-Sales Service

Service Guarantee

1. Online Training Services

If assistance is needed, we will provide online installation and commissioning services, as well as comprehensive operation training for you. Meanwhile, we also offer 24/7 online training support for end users throughout the year.

2. Professional After-Sales Service

According to the type of instrument, we can provide specialized maintenance services. Our goal is to become the highest-quality and most reliable instrument supplier in the market. We welcome your valuable opinions and suggestions to help us continuously improve our service quality.

Logistics and Shipping

Worldwide Shipping: We have extensive experience in shipping goods to Asia, Europe, the Middle East, and other regions.

Secure Packaging: Laboratory instruments are carefully packed to ensure they are properly secured and protected during transit.

International Certification

Hydrocarbons Tester

FTIR

ISO 9001 Certification

ASTM Certificate

1.This standard is used for the measurement of total recoverable petroleum hydrocarbons (TRPHs) extracted with supercritical carbon dioxide from sediment, soil and sludge samples. 2. It is not applicable to the measurement of gasoline and other volatile petroleum fractions, because of evaporative losses.

HKL

Hong Kong,China

deliver as soon as received payment

30 sets one month

Product Info