• ASTM D2163 GC determining Hydrocarbons in LPG
  • video

ASTM D2163 GC determining Hydrocarbons in LPG

  • HKL
  • Hong Kong,China
  • deliver as soon as received payment
  • 30 sets one month
1. This test method offers a way to quantitatively measure the amount of specific hydrocarbons in liquefied petroleum (LP) gases and in mixtures of propane and propene, except for high-purity propene. The hydrocarbon range is from C1 to C5. Component concentrations are determined in the range of 0.01 to 100 volume percent. 2. Hydrocarbon composition data for liquefied petroleum gases (LPG) and propene mixtures can be used to calculate physical properties such as relative density, vapor pressure, and motor octane number. The precision and accuracy of such compositional data are extremely important when they are applied to calculate various properties of these petroleum products.

HKL-2163 GC for determining Hydrocarbons in LPG

Overview

HKL-2163 GC for determining Hydrocarbons in LPG conforms to ASTM D2163 Standard Test Method Determination of Hydrocarbons in Liquefied Petroleum (LP) Gases and Propane/Propene Mixtures by Gas Chromatography. This test method offers a way to quantitatively measure the amount of specific hydrocarbons in liquefied petroleum (LP) gases and in mixtures of propane and propene, except for high-purity propene. The hydrocarbon range is from C1 to C5. Component concentrations are determined in the range of 0.01 to 100 volume percent.

Hydrocarbon composition data for liquefied petroleum gases (LPG) and propene mixtures can be used to calculate physical properties such as relative density, vapor pressure, and motor octane number. The precision and accuracy of such compositional data are extremely important when they are applied to calculate various properties of these petroleum products.

Features

  1. With a 320×240 dot matrix 5.7-inch large-screen liquid crystal display, real-time monitoring of temperatures and operating conditions for each channel is perfectly achieved.

  2. Automatic startup self-test, six independent temperature control channels, and seven-stage program temperature rise function.

  3. Wide-range self-diagnosis function: When an instrument failure occurs, it automatically displays the fault phenomenon, fault code, and fault cause, helping you quickly identify and resolve issues to maintain optimal laboratory working conditions.

  4. Over-temperature protection function: Allows arbitrary setting of protection temperatures. If any channel exceeds the set temperature, the instrument automatically cuts off power and alarms.

  5. Carrier gas interruption and leakage protection function: When carrier gas pressure is insufficient, the instrument automatically cuts off power and stops heating, effectively protecting the chromatographic column and thermal conductivity detector from damage.

  6. Intelligent fuzzy control rear-door opening system automatically tracks temperature and dynamically adjusts the rear-door opening angle, enabling precise temperature control even near room temperature.

  7. Equipped with packed column on-column injection, glass liner injection, and capillary split/splitless injection devices with septum purge function, as well as support for installing gas samplers.

  8. High-precision dual-stabilized gas flow paths allow installation of up to four detectors simultaneously.

  9. Advanced gas flow design enables simultaneous use of hydrogen flame ionization detector and thermal conductivity detector.

  10. Eight external event functions support multi-valve switching.

  11. Optional electronic flow/pressure display system and built-in workstation device.

Technical Parameters

  1. Temperature Control Range: Ambient temperature +5°C to 400°C, Increment: 0.1°C

  2. Temperature Control Accuracy: Better than ±0.1°C

  3. Programmed Temperature Ramp: Seven stages

  4. Heating Rate: 0.1 to 40°C/min

  5. Main Unit Dimensions: 555 × 525 × 485 mm

Chromatogram

ASTM D2163

FAQ

  1. Q1: What standards does this product (HKL-2163 GC for determining Hydrocarbons in LPG) comply with?

    A:HKL-2163 GC for determining Hydrocarbons in LPG conforms to ASTM D2163 Standard Test Method Determination of Hydrocarbons in Liquefied Petroleum (LP) Gases and Propane/Propene Mixtures by Gas Chromatography. This test method offers a way to quantitatively measure the amount of specific hydrocarbons in liquefied petroleum (LP) gases and in mixtures of propane and propene, except for high-purity propene. The hydrocarbon range is from C1 to C5. Component concentrations are determined in the range of 0.01 to 100 volume percent.

  2. Q2: Significance and use of HKL-2163 GC for determining Hydrocarbons in LPG?

    A:Hydrocarbon composition data for liquefied petroleum gases (LPG) and propene mixtures can be used to calculate physical properties such as relative density, vapor pressure, and motor octane number. The precision and accuracy of compositional data like these are absolutely critical when they are used to estimate the various properties of these petroleum products.

  3. Q3: What is the minimum order quantity? How long is the delivery lead time?

    A: The minimum order quantity is one unit, and delivery is approximately 20 days after advance payment.

  4. Q4: How can I get a product quotation?

    A: Please submit your requirements via the contact page on our official website or customer service email, and we will contact you within 24 hours with a detailed quotation.

  5. Q5: Do you offer customized solutions?

    A: Yes, we can provide customized instrument configurations and testing solutions based on the customer’s specific application need

GC

About us

Founded in 2018, Hong Kong Laboratory Technology Limited has very quickly risen to be one among the leading suppliers of supply chain solutions in the scientific instrument industry. Having been involved in the industry for more than 8 years, we have established a connection of more than 500 research and development clients with a network of suppliers which includes one of the largest group of over 50 top manufacturers, thus enabling a simple flow from innovation to mass production. We implement a strict quality control system on all our processes. As a result, our main product lines comply not just with internationally recognized standards such as ISO 9001, ASTM, and IP, but they also satisfy the stringent requirements of the ISO/IEC 17025 calibration standard. Our strong dedication to accuracy and quality has earned us the status of the foremost partner of scientific research institutions, hospitals, environmental protection agencies, as well as the mining and petrochemical industries.

Company Advantages

(1)Full-Chain Resource Integration Capability

(2)Professional Technical Service Team

(3)Rich Industry Practical Cases

(4)Reliable After-Sales Service

Service Guarantee

1. Online Training Services

We will gladly guide you through the entire process. Through online means, we can even handle installation and commissioning, and provide you with extensive training that will get you started in no time. Furthermore, to ensure that your team continues to succeed, we give you access to online training support 24/7, 365 days a year.

2. Professional After-Sales Service

Our maintenance plans are carefully tailored to various types of instruments. We aim to become your trusted partner who always offers excellent quality and dependable instruments. We really appreciate your participation in providing valuable feedback and proposals that will help us improve our services and satisfy your requirements even more. We are grateful to have you on this path together.

Logistics and Shipping

Worldwide Shipping:We know well the process of shipping goods to Asia, Europe, the Middle East, and other parts of the world thanks to our extensive experience.

Secure Packaging:Lab instruments are expertly packed in order to guarantee they are safely secured and shielded from any harm while being transported.

International Certification

Gas Chromatograph ASTM D2163

ISO 9001 Certification

ASTM Certificate

1. This test method offers a way to quantitatively measure the amount of specific hydrocarbons in liquefied petroleum (LP) gases and in mixtures of propane and propene, except for high-purity propene. The hydrocarbon range is from C1 to C5. Component concentrations are determined in the range of 0.01 to 100 volume percent. 2. Hydrocarbon composition data for liquefied petroleum gases (LPG) and propene mixtures can be used to calculate physical properties such as relative density, vapor pressure, and motor octane number. The precision and accuracy of such compositional data are extremely important when they are applied to calculate various properties of these petroleum products.

HKL

Hong Kong,China

deliver as soon as received payment

30 sets one month

Product Info

Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)