1. The instrument not only adheres to the ISO 10993-7 standard but also qualifies as a complete testing instrument, which guarantees the generation of accurate and trustworthy results. 2. The Gas Chromatograph for Ethylene Oxide is tailored to the tracing of ethylene oxide leftover in medical devices.

HKL10993 Gas Chromatograph for Ethylene Oxide

Overview

The HKL-10993 Gas Chromatograph for Ethylene Oxide conforms to the ISO 10993.7 Medical devices. Biological evaluation of medical devices. Part 7: Ethylene oxide sterilization residuals. This tool determines the remaining level of ethylene oxide in medical instruments following their sterilization with ethylene oxide. As per the standard, the detection of very trace levels of residues is necessary (usually, EO levels are expressed in µg/g), therefore, this equipment, thanks to its high sensitivity and very low detection limit, can meet these requirements.

Features

  1. It comes with a 5.7-inch LCD touch screen, physical buttons that are easy and comfortable to use and a very friendly user interface that makes it very difficult for the operator to make a mistake.

  2. The rotary sample inlet and quick-change liner conforming to international standards enable the fast exchange of the liner and less amount of time spent on cleaning and maintenance.

  3. The equipment is fitted with a highly-sensitive Flame Ionization Detector (FID) that comes with automatic ignition and complies with the worldwide performance specifications.

  4. The built-in onboard workstation and USB interface provide guaranteed wide compatibility with different computer systems.

  5. The CPU self-diagnostics that are built-in help quickly pinpoint and resolve issues related to operations.

  6. A larger column oven facilitates accuracy and reproducibility of analyses.

  7. A large-capacity column oven, together with a powerful fan and an intelligent rear-exhaust cooling system, greatly speeds up the cooling process.

  8. Uses corrosion-resistant, interference-free circuitry and is also equipped with an anti-overheating feature to ensure dependable operation.

  9. Enables multi-step temperature programming, external event control, and timed cyclic injections through a multi-valve configuration.

  10. Optional liquid autosampler can be purchased separately to allow fully automated operational workflows.

  11. Overall dimensions measure 610 mm in width, 515 mm in depth, and 520 mm in height.

Technical Parameters

  1. Inlet System indicators

    1)Sample Inlet Design: Flip-top Sealing System, Quick-release Modularization.

    2)Maximum Operating Temperature: 400°C

    3)Maximum Installable Inlets: up to 3 inlets

    4)Injection Modes: Packed column injection, Split capillary column injection, Valve injection

  2. Temperature Control Indicators

    1)Column Dimensions: 300 × 300 × 250 mm (L × W × D)

    2)Temperature Control Range: Ambient +5°C ~ 400°C, increment 0.1°C

    3)Temperature Setting Increment: 0.1°C

    4)Temperature Control Accuracy: ±0.1°C

    5)Programmed Temperature Ramp: 7 stages

    6)Heating Rate: 0 ~ 40°C/min, Inter-stage Hold Time: 0 ~ 999 min

    7)Cooling Performance (Ambient 19°C): ≤ 4 min (from 300°C to 100°C)

FAQ

  1. Q1: What standards does this product (HKL10993 Gas Chromatograph for Ethylene Oxide) comply with?

    A:The HKL-10993 Gas Chromatograph for Ethylene Oxide conforms to the ISO 10993.7 Medical devices. Biological evaluation of medical devices. Part 7: Ethylene oxide sterilization residuals. This tool determines the remaining level of ethylene oxide in medical instruments following their sterilization with ethylene oxide. As per the standard, the detection of very trace levels of residues is necessary (usually, EO levels are expressed in µg/g), therefore, this equipment, thanks to its high sensitivity and very low detection limit, can meet these requirements.

  2. Q2: How can I obtain a product quotation?

    A: Kindly write to us with your details through the contact page on our official website or customer service email, and we shall get back to you within 24 hours with a detailed quotation.

  3. Q3: Do you support customized solutions?

    A: Yes, we can provide customized instrument configurations and testing solutions based on the customer’s specific application needs.

  4. Q4: What is the minimum order quantity? How long is the delivery lead time?

    A: The smallest number of units you can order is one, and the delivery time is usually about 20 days after you have made the payment in advance.

  5. Q5: What kind of after-sales service do you offer?

    A: We promise you an extensive and dependable after-sales support network to cover the entire life of the product. The following are parts of this support network: (1) Quick Reaction: We have a dedicated customer service team constantly working to guarantee your issues will be responded to without delay. (2) Expert Technical Engineer Assistance: A knowledgeable group of engineers is remotely to provide immediate resolution to technical problems. (3) Continuous Empowerment: We don’t just train your team once and forget about it. Long-term online training and regular guidance help your team to get the most out of the instrument. Besides problem solving, our aim is to be a trustworthy laboratory partner who you can rely on 100%. Reliable instrument functioning and correct data entail that you can dedicate more time to your scientific work without worries.

  6. Q6: What international shipping options do you support?

    A: We provide several international shipping choices that can adapt to your personal needs: (1) International Express: Our collaboration is with the top couriers such as DHL, FedEx, UPS, and TNT. This method is best suited for small and expensive products. (2) Air Freight: This mode of shipping is a cheap option for the delivery of medium-sized goods. (3) Sea Freight: Perfect for large-volume shipping, it offers Full Container Load (FCL) and Less than Container Load (LCL) services at your disposal. Usually, the delivery time varies from 20 to 40 days depending on the destination port. (4) Rail Freight: Serving the continent of Eurasia (for example, Central Asia, Russia, Europe), in particular, offering dependable and efficient China-Europe Railway Express services.

Ethylene Oxide Tester

About us

Hong Kong Laboratory Technology Limited has been a trustworthy collaborator in the scientific and industrial equipment market since 2018. In the past eight years, we have not only built a network of 50 leading manufacturers but also served more than 500 clients as a specialized supply chain company. Our main strength lies in bridging Research and Development innovations with production realities and throwing in an extensively implemented quality management system for good measure. Alongside our main products being able to meet all the specifications of the internationally recognized standards like ISO 9001, ASTM, and IP, they are also designed to fulfill the requirements of the calibration competence standard ISO/IEC 17025. Instruments from our company, therefore, enjoy the reputation of being the first choice for research labs, petrochemical and mining industries, healthcare facilities, and environmental monitoring stations worldwide.

Company Advantages

(1)Full-Chain Resource Integration Capability

(2)Professional Technical Service Team

(3)Rich Industry Practical Cases

(4)Reliable After-Sales Service

Service Guarantee

1. Online Training Services

Feel free to check with us at any stage of your project. Besides installation and commissioning guidance over the internet, we can also do comprehensive training for you to become independent. Furthermore, to guarantee that your team continue to perform at their best, we have made available 24/7 online training support, all year round.

2. Professional After-Sales Service

We offer plans for maintenance that are specific to different types of instruments. We aspire to be your first choice partner, known for supplying you with top-notch and most reliable devices. We always look forward to hearing your feedback and ideas to enhance our offerings and better meet your needs. We appreciate your willingness to walk with us in this co-creative path.

Logistics and Shipping

Worldwide Shipping: We are very familiar with international logistics that we can guarantee the smooth delivery to Asia, Europe, and the Middle East destinations.

Secure Packaging: Laboratory instruments are carefully packed to ensure that they are properly secured and protected from any damage during transportation.

International Certification

Gas Chromatograph GC

ISO 9001 Certification

ASTM Certificate

1. The instrument not only adheres to the ISO 10993-7 standard but also qualifies as a complete testing instrument, which guarantees the generation of accurate and trustworthy results. 2. The Gas Chromatograph for Ethylene Oxide is tailored to the tracing of ethylene oxide leftover in medical devices.

HKL

Hong Kong,China

deliver as soon as received payment

30 sets one month

Product Info

Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)