• ASTM D6751 GC for methanol in biodiesel
  • video

ASTM D6751 GC for methanol in biodiesel

  • HKL
  • Hong Kong,China
  • deliver as soon as received payment
  • 30 sets one month
1. HKL-6751 GC for methanol in biodiesel complies with ASTM D6751 Standard and EN 14214 Requirements and test methods. 2. The ASTM D6751 and EN 14214 standards specify the maximum allowable concentration of contaminants in finished pure biodiesel (B100) and other physicochemical characteristics required for safe and reliable engine operation.

HKL-6751 GC for methanol in biodiesel

Overview

HKL-6751 GC for methanol in biodiesel complies with ASTM D6751 Standard Specification for Biodiesel Fuel Blend Stock (B100) for Middle Distillate Fuels and EN 14214 Automotive fuels – Fatty acid methyl esters (FAME) for diesel engines – Requirements and test methods. Compared to traditional petroleum diesel, biodiesel has a smaller environmental impact. Biodiesel can be used as a pure fuel or mixed with petroleum diesel in any proportion. The ASTM D6751 and EN 14214 standards specify the maximum allowable concentration of contaminants in finished pure biodiesel (B100) and other physicochemical characteristics required for safe and reliable engine operation.

Features

  1. HKL-6751 GC for methanol in biodiesel adopts 10.2 inch touch LCD. It can display the temperature of each way and Real-Time Operation conditions, so as to achieve the on line monitoring.

  2. POST, indenpendt temperature control of six ways and five stages program temperature rise.

  3. Self-diagnosis function: If there is a failure, the apparatus will automatic display the fault phenomenon, code and cause to help the operator find and solve the fault in short time.

  4. Over temperature protection: The protective temperature can be set freely,if there is a way exceeds the setting temperature, the appratus will automatic power off and alarm.

  5. Carrier gas protection: When the carrier gas is underpressure, the apparatus will automatic power off and stop heating to protect chromatographic column and thermal conductivity detector effectively.

  6. Intelligent fuzzy control back gate system: Automatic tracing temperature and dynamic regulate the angle of the bakc gate. The apparatus can do precision control under room condition.

  7. Equiped with packed column chapiter sampling, glass-lined sampling and capillary split/splitless sampling device with membrane cleaning fucntion. The apparatus also can install the gas sampler.

  8. High precision and stable dual way. Maximum can install 4 kinds of detector.

  9. Advanced gas rutine, it is available to use hydrogen flame detector and thermal conductivity detector.

  10. Both FID and capillary tube inlet are EPC controlled.

  11. Electronic flow pressure display system and internal work station device can be selected.

  12. 19 digits automatic liquid sampler.

Technical Parameters

Temperature control index

  1. Temperature control range:Room temperature 5℃~400℃, Increment: 0.1℃

  2. Temperature control accuracy: Better than ±0.1℃

  3. Temperature programming:

    (1) 5 stages, constant temperature time between stage:0~999min

    (2) Increment:0.1min,Temperature increment: 0.1℃

    (3) Heating rate: Maximum 40℃/min below 200℃

    (4) Maximum 20℃/min above 200℃

LOD


Compound

Max % m/m (EN 14214)

Glycerin

0.02

Mono-glycerides

0.8

Di-glycerides

0.2

Tri-glycerides

0.2

Total Glycerin

0.25


FAQ

  1. Q1: What standards does this product (HKL-6751 GC for methanol in biodiesel) comply with?

    A: HKL-6751 GC for methanol in biodiesel complies with ASTM D6751 Standard Specification for Biodiesel Fuel Blend Stock (B100) for Middle Distillate Fuels and EN 14214 Automotive fuels – Fatty acid methyl esters (FAME) for diesel engines – Requirements and test methods. Compared to traditional petroleum diesel, biodiesel has a smaller environmental impact. Biodiesel can be used as a pure fuel or mixed with petroleum diesel in any proportion. The ASTM D6751 and EN 14214 standards specify the maximum allowable concentration of contaminants in finished pure biodiesel (B100) and other physicochemical characteristics required for safe and reliable engine operation.

  2. Q2: What international shipping methods do you support?

    A: An air generator is a device that produces a clean, moisture-free, and oil-free compressed air supply for the use of analytical instruments in the laboratory. It is widely used as a secondary gas supply for such devices as gas chromatographs (GC), nitrogen generators, atomic absorption spectrophotometers (AAS), total organic carbon analyzers (TOC), and thermal analyzers, which allows the replacement of the conventional high-pressure cylinders and the realization of them continuous and stable gas supply.

  3. Q3: Do you offer customized solutions?

    A: Yes, we can provide customized instrument configurations and testing solutions based on the customer’s specific application needs.

  4. Q4: Do you provide online training services?

    A: To help you thrive, we are always at your service for your online installation, commissioning, and complete operational training. For your employees, we also offer 24×7 online training and support availability, 365 days a year.

  5. Q5: What is the minimum order quantity? How long is the delivery lead time?

    A: The minimum order quantity is one unit, and delivery is approximately 20 days after advance payment.

  6. Q6: What application areas do your instruments cover?

    A: Our instruments are widely used in research institutions, petrochemical and mining industries, medical institutions, and environmental protection departments. High-quality products have earned widespread market acceptance and customer trust.

ASTM D6751

About us

Hong Kong Laboratory Technology Limited specializes in supply chain integration and full-chain technical services for laboratory instruments. With years of industry expertise, our company operates under a stringent quality management system, complying with multiple international standards including ISO 9001, ASTM, and IP requirements. The core products not only comply with the ISO/IEC 17025 instrument calibration and testing standards, but are also widely used in research institutions,petrochemical andmining industries, medical institutions,and environmental protection departments. This high-standard quality has earned broad market and customer trust.

Company Advantages

(1)Full-Chain Resource Integration Capability

(2)Professional Technical Service Team

(3)Rich Industry Practical Cases

(4)Reliable After-Sales Service

Service Guarantee

1. Online Training Services

If assistance is needed, we will provide online installation and commissioning services, as well as comprehensive operation training for you. Meanwhile, we also offer 24/7 online training support for end users throughout the year.

2. Professional After-Sales Service

According to the type of instrument, we can provide specialized maintenance services. Our goal is to become the highest-quality and most reliable instrument supplier in the market. We welcome your valuable opinions and suggestions to help us continuously improve our service quality.

Logistics and Shipping

Worldwide Shipping: We have extensive experience in shipping goods to Asia, Europe, the Middle East, and other regions.

Secure Packaging: Laboratory instruments are carefully packed to ensure they are properly secured and protected during transit.

International Certification

GC Gas Chromatograph

ISO 9001 Certification

ASTM Certificate

1. HKL-6751 GC for methanol in biodiesel complies with ASTM D6751 Standard and EN 14214 Requirements and test methods. 2. The ASTM D6751 and EN 14214 standards specify the maximum allowable concentration of contaminants in finished pure biodiesel (B100) and other physicochemical characteristics required for safe and reliable engine operation.

HKL

Hong Kong,China

deliver as soon as received payment

30 sets one month

Product Info

Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)