• ASTM D6160 GC for Determination of PCBs
  • video

ASTM D6160 GC for Determination of PCBs

  • HKL
  • Hong Kong,China
  • deliver as soon as received payment
  • 30 sets one month
1. This test method Provides sufficient PCB data for many regulatory requirements. While the most common regulatory level is 50ppm (dry weight corrected), lower limits are used in some locations. Since sensitivities will vary for different types of samples, one shall demonstrate a sufficient method detection limit for the matrix of interest. 2. This test method provides for more sample clean-up options, utilizes a capillary column for better pattern recognition and interference discrimination, and includes both a qualitative screening and a quantitative results option.

HKL-6160 GC for Determination of PCBs

Overview

HKL-6160 GC for Determination of PCBs conforms to ASTM D6160 Standard Test Method for Determination of Polychlorinated Biphenyls (PCBs) in Waste Materials by Gas Chromatography. This test method Provides sufficient PCB data for many regulatory requirements. While the most common regulatory level is 50ppm (dry weight corrected), lower limits are used in some locations. Since sensitivities will vary for different types of samples, one shall demonstrate a sufficient method detection limit for the matrix of interest.

This test method differs from Test Method D4059 in that it provides for more sample clean-up options, utilizes a capillary column for better pattern recognition and interference discrimination, and includes both a qualitative screening and a quantitative results option.

Chromatogram


ASTM D6160
















Configuration


NO.

Name

Specification

Qty.

1

GC for PCBs

1.Big LCD display, boot self-checking, wide range diagnosis function, intelligent fuzzy control system, opening after power; over temperature protection function, six-stage rise

2.Configuration: main host + capillary tube injection port (split/splitless)

1 set

2

ECD + Amplifier board

Adopts Ni63370MBq radiation source, working temperature can reach 350℃, Suitable for the analysis of halides such as pesticide residues

Analysis: Pesticide Residues Organochlorine

1 set

3

Work station

Dedicated for double channels

1 set

4

Capillary Column

For PCBs

1pc

5

PC + Printer

Self-prepared

1 set

6

Nitrogen cylinder

Purity: 99.999

Cylinder + reducing valve

Self-prepared

1 set


FAQ

  1. Q1: What standards does this product (HKL-6160 GC for Determination of PCBs) comply with?

    A:HKL-6160 GC for Determination of PCBs conforms to ASTM D6160 Standard Test Method for Determination of Polychlorinated Biphenyls (PCBs) in Waste Materials by Gas Chromatography. This test method Provides sufficient PCB data for many regulatory requirements. While the most common regulatory level is 50ppm (dry weight corrected), lower limits are used in some locations. Since sensitivities will vary for different types of samples, one shall demonstrate a sufficient method detection limit for the matrix of interest. This test method differs from Test Method D4059 in that it provides for more sample clean-up options, utilizes a capillary column for better pattern recognition and interference discrimination, and includes both a qualitative screening and a quantitative results option.

  2. Q2: What international shipping methods do you support?

    A: We have several flexible international shipping methods that you can choose from based on your requirements:(1) International Express: We work with some of the most reliable courier companies in the world like DHL, FedEx, UPS, and TNT which would be an excellent choice for small quantities and valuable items.(2) Air Freight: Perfect solution for medium size shipments which provide a very good balance between price and service.(3) Shipping by Sea: If you are placing a very large order, this mode of transport will be a great option for you since it can accommodate FCL and LCL services with an approximate transit time of 20-40 days depending on the destination port.(4) Rail Freight: This options is highly recommended for those living in the areas across the Eurasian continent (e.g. Central Asia, Russia, Europe) as it will give you stable and efficient China-Europe Railway Express services.

  3. Q3: What is the minimum order quantity? How long is the delivery lead time?

    A: The smallest number of units you can order is one, and the goods will be delivered roughly 20 working days after the receipt of your advance payment.

  4. Q4: How can I obtain a product quotation?

    A: Kindly send your requirements through the contact page or customer service email of our official website, and we will reach out to you within 24 hours with a detailed quotation.

  5. Q5: What kind of after-sales service do you support?

    A: Throughout the entire lifecycle of the product, we promise to deliver a comprehensive and trustworthy after-sales support system to you. This system comprises: (1) Fast Reaction: You can always call on a skilled customer service team who work round the clock so that your requests find prompt answers. (2) Expert Technical Engineer Assistance: A highly-qualified engineer team is ready to offer both remote diagnostics to allow you to overcome technical problems in the shortest time possible. (3) Continuous Empowerment: We provide your team with consistent online training and support so that they can make the most of the instrument’s features. Besides just troubleshooting issues, we aim to be your lab’s trusted partner capable of delivering you with stable instrument operation and accurate, reliable data, thereby allowing you to concentrate more on your scientific research.

GC

About us

Hong Kong Laboratory Technology Limited was established in 2018 and has been a part of the instrument industry for over eight years. We are the representatives of 50+ brands and have served 500+ clients. As a professional instrument supply chain service provider, we have developed core supply resources covering research and development, production, and more. Leveraging the industry experience we have accumulated over the years, the company strictly implements a quality management system. Our top products comply with a range of international standards such as ISO 9001, ASTM, and IP and they have also met the requirements of the ISO/IEC 17025 standard for instrument calibration and testing. These products have been widely used in fields like research centers, petrochemical and mining industries, healthcare, environment protection services, etc. Apart from enabling you to purchase the most economical tools and devices, we also provide expert technical advice concerning both the selection process and the after-sales service.

Company Advantages

(1)Full-Chain Resource Integration Capability

(2)Professional Technical Service Team

(3)Rich Industry Practical Cases

(4)Reliable After-Sales Service

Service Guarantee

1. Online Training Services

We are always available to offer our assistance and guidance throughout the entire process. We can be your online installation and commissioning, as well as your thorough training providers, to enable you to be self-sufficient. In addition, for your team’s continuous success, we provide online training support 24/7, 365 days a year.

2. Professional After-Sales Service

We offer expert maintenance programs tailored to a variety of instruments types. Our goal is to become the main partner you can rely on for the highest quality and most dependable instruments. Your comments and feedback are very important to us and we wish to continue to improve our services to satisfy your requirements. Thanks for joining us in our collaborative journey.

Logistics and Shipping

Worldwide Shipping:Our team has successfully handled the shipment of goods to Asia, Europe, and Middle East among other places.

Secure Packaging: Laboratory instruments are carefully packed to ensure that they will be adequately secured and protected during the trip.

International Certification

Gas Chromatograph ASTM D6160

ISO 9001 Certification

ASTM Certificate

1. This test method Provides sufficient PCB data for many regulatory requirements. While the most common regulatory level is 50ppm (dry weight corrected), lower limits are used in some locations. Since sensitivities will vary for different types of samples, one shall demonstrate a sufficient method detection limit for the matrix of interest. 2. This test method provides for more sample clean-up options, utilizes a capillary column for better pattern recognition and interference discrimination, and includes both a qualitative screening and a quantitative results option.

HKL

Hong Kong,China

deliver as soon as received payment

30 sets one month

Product Info

Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)