• AOAC 2007.01 Pesticide Residue Analysis by GC
  • video

AOAC 2007.01 Pesticide Residue Analysis by GC

  • HKL
  • Hong Kong,China
  • deliver as soon as received payment
  • 30 sets one month
1. The instrument's measurements conform to AOAC Official Method 2007.01 and can measure various pesticide residues. 2. Modular detection platform: Supports free combination and rapid switching of multiple detectors such as FPD/NPD/ECD/MSD.

HKL-2007 Gas Chromatograph for Pesticide Residue

Overview

The HKL-2007 Gas Chromatograph for Pesticide Residue conforms to the AOAC Official Method 2007.01 Pesticide Residues in Foods by Acetonitrile Extraction and Partitioning with Magnesium Sulfate Gas Chromatography / Mass Spectrometry and Liquid Chromatography / Tandem Mass Spectrometry. AOAC Official Method 2007.01 is a standard method for the determination of multiple pesticide residues in food, based on the QuEChERS method. The method integrates 1% acetic acid in acetonitrile extraction, salting-out with acetate buffer, and cleanup by dispersive solid-phase extraction (dSPE) using PSA/MgSO₄. Besides qualitative and quantitative analysis, it utilizes GC/MS and LC/MS/MS. It is suitable for fruits and vegetables with a high content of water.

Features

  1. It features a 5.7-inch LCD screen, ergonomic physical controls along with an intuitive user interface.

  2. Rotary sample inlet with quick-change liner that meets international standards making it easy to change the liner and maintenance.

  3. Highly sensitive and capable of auto-ignition FID at the same time complies with world-class performance standards.

  4. Embedded workstation and USB interface enable compatibility with a wide range of computers.

  5. With the internal CPU self-diagnostics, faults can be identified rapidly.

  6. A longer column oven gives more accurate analysis and consistent results.

  7. A large column oven, a powerful fan, and an intelligent rear-exhaust cooling system work jointly to speed up the cooldown period.

  8. Circuits which do not corrode and are interference-free with additional protection against over-temperature.

  9. It can do temperature programming at different steps, control the external event, and make timed cyclic injections by using a multi-valve setup.

  10. The liquid autosampler is optional and allows fully automated operation.

  11. Overall dimensions: 610 × 515 × 520 mm

Technical Parameters

  1. Inlet System Specifications

    1) Sample Inlet Configuration: Flip-top Sealing Mechanism with Quick-release Modular Structure

    2) Maximum Operational Temperature Rating: 400°C

    3) Maximum Inlet Installation Capacity: Up to 3 units

    4) Available Injection Methods: Packed Column Injection, Split Capillary Column Injection, Valve-driven Injection

  2. Temperature Control Indicators

    1)Column Dimensions: 300 × 300 × 250 mm (L × W × D)

    2)Temperature Control Range: Ambient +5°C ~ 400°C, increment 0.1°C

    3)Temperature Setting Increment: 0.1°C

    4)Temperature Control Accuracy: ±0.1°C

    5)Programmed Temperature Ramp: 7 stages

    6)Heating Rate: 0 ~ 40°C/min, Inter-stage Hold Time: 0 ~ 999 min

    7)Cooling Performance (Ambient 19°C): ≤ 4 min (from 300°C to 100°C)

FAQ

  1. Q1: What standards does this product (HKL-2007 Gas Chromatograph for Pesticide Residue) comply with?

    A: The HKL-2007 Gas Chromatograph for Pesticide Residue conforms to the AOAC Official Method 2007.01 Pesticide Residues in Foods by Acetonitrile Extraction and Partitioning with Magnesium Sulfate Gas Chromatography / Mass Spectrometry and Liquid Chromatography / Tandem Mass Spectrometry. AOAC Official Method 2007.01 is a standard method for the determination of multiple pesticide residues in food, based on the QuEChERS method. The acetone extraction process includes adding 1% acetic acid, salting-out acetate buffer, and PSA/MgSO₄ dSPE clean-up followed by GC/MS and LC/MS/MS for qualitative and quantitative analysis. The method can be used on fruits and vegetables that contain a high water content.

  2. Q2: What is the applicable scope of HKL-2007 Gas Chromatograph for Pesticide Residue?

    A: This is also valid for the use of pesticides in grapes, lettuces, and oranges such as: atrazine, azoxystrobin, bifenthrin, carbaryl, chlorothalonil, chlorpyrifos, chlorpyrifos-methyl, l-cyhalothrin (incurred in lettuces), cyprodinil, o,p’-DDD, dichlorvos, endosulfan sulfate, ethion (incurred in oranges), imazalil, imidacloprid, kresoxim-methyl (incurred in grapes), linuron, methamidophos, methomyl, permethrins (incurred in lettuces) procymidone, pymetrozine, tebuconazole, thiabendazole (incurred in oranges), tolylfluanid (degraded in lettuces), and trifluralin. Pesticides representative of the study analytes were selected in representative matrixes and it is likely the method will also be effective for many other similar pesticides and matrixes as well. LOQ (limit of quantitation) values were shown to be less than 10 ng/g.

  3. Q3: What is the minimum order quantity? How long is the delivery lead time?

    A: We accept orders of only one unit as the minimum. Payment in advance is required and delivery normally takes about 20 days.

  4. Q4: Do you provide online training services?

    A: If you need help, we will connect you with our online installation and commissioning services team together with a thorough operational training course. Besides, we provide user training, online support, 24/7, all year round.

  5. Q5: What international shipping options do you support?

    A: To fit your needs, we provide the following flexible international shipping solutions: (1) International Express: Working with globally top courier companies like DHL, FedEx, UPS, and TNT, perfect for small quantity and high-value items. (2) Air Freight: Best for medium-size shipments with the great balance of cost and service. (3) Sea Freight: Ideal for large-volume orders. It provides Full Container Load (FCL) and Less than Container Load (LCL) services. The transit time is around 20–40 days (depending on the destination port). (4) Rail Freight: Our rail freight can reach clients throughout the Eurasian continent (e.g., Central Asia, Russia, Europe), and we continuously supply efficient and stable China-Europe Railway Express services.

Pesticide Residues Analyzer

About us

Since 2018, Hong Kong Laboratory Technology Limited has quickly grown to be recognized as one of the top suppliers of supply chain solutions in the scientific instrument industry.With more than 8 years of experience in this field, to this date, we have connected over 500 Research and Development customers to one of the largest supplier networks comprising over 50 leading manufacturers, thus facilitating a smooth transition from innovation to mass production. Our fundamental products are designed to meet the requirements of various international standards such as ISO 9001, ASTM, and IP. The main products are not only in line with ISO/IEC 17025 standards for instrument calibration and testing but have also been adopted by research institutes, petrochemical and mining industries, medical institutions as well as environmental protection agencies. The high level of quality has gained wide recognition in the market and among customers.

Company Advantages

(1)Full-Chain Resource Integration Capability

(2)Professional Technical Service Team

(3)Rich Industry Practical Cases

(4)Reliable After-Sales Service

Service Guarantee

1. Online Training Services

We are here to support you at every step. If you want, we can do the installation and commissioning for you online. Besides that, you will get comprehensive training for operating the system. And if your team wants to continue learning, we have a live online training support service that runs 24 hours a day, 365 days a year.

2. Professional After-Sales Service

We offer special maintenance plans for all types of instruments. We aim to be your partner of choice and be known for providing the highest quality and most reliable instruments. We always look for your precious opinions and suggestions to help us improve our services in a way that can satisfy you more. Thanks for being together on our joint path.

Logistics and Shipping

Worldwide Shipping: We have very well established logistics channels covering Asia, Europe, the Middle East, and other parts of the world, through which we can offer you efficient and reliable international shipping services.

Secure Packaging: Laboratory instruments are packed with great care to ensure that they are entirely secured and protected from damages during transportation.

International Certification

Gas Chromatograph GC

ISO 9001 Certification

ASTM Certificate

1. The instrument's measurements conform to AOAC Official Method 2007.01 and can measure various pesticide residues. 2. Modular detection platform: Supports free combination and rapid switching of multiple detectors such as FPD/NPD/ECD/MSD.

HKL

Hong Kong,China

deliver as soon as received payment

30 sets one month

Product Info

Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)