• ASTM D4059 GC for PCBs in Insulating Liquids
  • video

ASTM D4059 GC for PCBs in Insulating Liquids

  • HKL
  • Hong Kong,China
  • deliver as soon as received payment
  • 30 sets one month
1. This test method describes a quantitative determination of the concentration of polychlorinated biphenyls (PCBs) in electrical insulating liquids by gas chromatography. 2. It also applies to the determination of PCB present in mixtures known as askarels, used as electrical insulating liquids.

HKL-4059 GC for PCBs in Insulating Liquids

Overview

HKL-4059 GC for PCBs in Insulating Liquids conforms to ASTM D4059 Standard Test Method for Analysis of Polychlorinated Biphenyls in Insulating Liquids by Gas Chromatography. This test method describes a quantitative determination of the concentration of polychlorinated biphenyls (PCBs) in electrical insulating liquids by gas chromatography. It also applies to the determination of PCB present in mixtures known as askarels, used as electrical insulating liquids.

The test specimen is diluted with a suitable solvent. The resulting solution is treated by a procedure to remove interfering substances after which a small portion of the resulting solution is injected into a gas chromatographic column. The components are separated as they pass through the column with carrier gas and their presence in the effluent is measured by an electron capture (EC) detector and recorded as a chromatogram. The test method is mad quantitative by comparing the sample chromatogram with a chromatogram of a known quantity of one or more standard Aroclors, obtained under the same analytical conditions.

United States governmental regulations mandate that electrical apparatus and electrical insulating fluids containing PCB be handled and disposed of through specific procedures. The procedure to be used for a particular apparatus or quantity of insulating fluid is determined by the PCB content of the fluid. The results of this analytical technique can be useful in selecting the appropriate handling and disposal procedure.

Quantification in this technique requires a peak-by peak comparison of the chromatogram of an unknown specimen with that of standard Aroclor test specimens obtained under identical conditions. The amount of PCB producing each peak in the standard chromatogram shall be known independently.

Chromatogram

ASTM D4059

FAQ

  1. Q1: What standards does this product (HKL-4059 GC for PCBs in Insulating Liquids) comply with?

    A:HKL-4059 GC for PCBs in Insulating Liquids conforms to ASTM D4059 Standard Test Method for Analysis of Polychlorinated Biphenyls in Insulating Liquids by Gas Chromatography. This test method describes a quantitative determination of the concentration of polychlorinated biphenyls (PCBs) in electrical insulating liquids by gas chromatography. It also applies to the determination of PCB present in mixtures known as askarels, used as electrical insulating liquids. The test specimen is diluted with a suitable solvent. The resulting solution is treated by a procedure to remove interfering substances after which a small portion of the resulting solution is injected into a gas chromatographic column. The components are separated as they pass through the column with carrier gas and their presence in the effluent is measured by an electron capture (EC) detector and recorded as a chromatogram. The test method is mad quantitative by comparing the sample chromatogram with a chromatogram of a known quantity of one or more standard Aroclors, obtained under the same analytical conditions.

  2. Q2: Significance and use of HKL-4059 GC for PCBs in Insulating Liquids?

    A:United States governmental regulations mandate that electrical apparatus and electrical insulating fluids containing PCB be handled and disposed of through specific procedures. The procedure to be used for a particular apparatus or quantity of insulating fluid is determined by the PCB content of the fluid. The results of this analytical technique can be useful in selecting the appropriate handling and disposal procedure.

  3. Q3: What is the minimum order quantity? How long is the delivery lead time?

    A: The minimum order quantity is one unit, and delivery is approximately 20 days after advance payment.

  4. Q4: How can I get a product quotation?

    A: Please submit your requirements via the contact page on our official website or customer service email, and we will contact you within 24 hours with a detailed quotation.

  5. Q5: What kind of after-sales service do you provide?

    A: Throughout the entire lifecycle of the product, we promise to deliver a comprehensive and trustworthy after-sales support system to you. This system comprises: (1) Fast Reaction: You can always call on a skilled customer service team who work round the clock so that your requests find prompt answers. (2) Expert Technical Engineer Assistance: A highly-qualified engineer team is ready to offer both remote diagnostics and on-site services to allow you to overcome technical problems in the shortest time possible. (3) Continuous Empowerment: We provide your team with consistent online training and support so that they can make the most of the instrument’s features. Besides just troubleshooting issues, we aim to be your lab’s trusted partner capable of delivering you with stable instrument operation and accurate, reliable data, thereby allowing you to concentrate more on your scientific research.

GC

About us

Established in 2018, Hong Kong Laboratory Technology Limited has been continuously associated with the instrument industry for more than eight years. We represent over 50 brands and our services have reached more than 500 clients. Being a professional instrument supply chain service provider, we have built up key supply resources not only in Research and Development but also in production and others. We make full use of the industry experience we have gathered over years and therefore our company rigorously follows a quality management system. Our best offerings are certified to various international standards like ISO 9001, ASTM, and IP. Also, they conform to the ISO/IEC 17025 standard for instrument calibration and testing. The products are being used in research institutes, petrochemical and mining industries, healthcare, environment protection services, etc., on a large scale. Not only do we help you locate the cheapest tools and equipment, but we also offer you proficient technical guidance on the sales process as well as the after-sales service.

Company Advantages

(1)Full-Chain Resource Integration Capability

(2)Professional Technical Service Team

(3)Rich Industry Practical Cases

(4)Reliable After-Sales Service

Service Guarantee

1. Online Training Services

We are ready to assist you regularly in making progress. When you require it, we can deliver remote installation and commissioning, along with comprehensive training that will enable you to operate. Furthermore, to support your team continuously, we make available 24-hour online training assistance, all year round.

2. Professional After-Sales Service

We offer tailor-made maintenance programs for various instrument types. Our goal is to be the one you turn to for partner, the supplier that is most recognized for the highest quality and the most trustworthy instruments in the market. We always look forward to hearing your precious feedback and ideas as it helps us serve you better and more than ever. Thank you for participating in our collective path.

Logistics and Shipping

Worldwide Shipping: We have a wealth of experience in shipping goods to Asia, Europe, Middle East and other parts of the world.

Secure Packaging: Laboratory instruments are methodically packaged using carefully selected materials and techniques, in order to make sure that they are completely fixed and will not be damaged even if they are moved two or more times.

International Certification

Gas Chromatograph ASTM D4059

ISO 9001 Certification

ASTM Certificate

1. This test method describes a quantitative determination of the concentration of polychlorinated biphenyls (PCBs) in electrical insulating liquids by gas chromatography. 2. It also applies to the determination of PCB present in mixtures known as askarels, used as electrical insulating liquids.

HKL

Hong Kong,China

deliver as soon as received payment

30 sets one month

Product Info

Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)