• ASTM D4291 GC for Trace Ethylene Glycol in Used Engine Oil
  • video

ASTM D4291 GC for Trace Ethylene Glycol in Used Engine Oil

  • HKL
  • Hong Kong,China
  • deliver as soon as received payment
  • 30 sets one month
1. HKL-4291 GC for Trace Ethylene Glycol in Used Engine Oil conforms to ASTM D4291 Standard Test Method for Trace Ethylene Glycol in Used Engine Oil. 2. It is used for the measurement of ethylene glycol as a contaminant in used engine oil. The ethylene glycol is supposed to be in the range from 5 to 200 mass ppm.

HKL-4291 GC for Trace Ethylene Glycol in Used Engine Oil

Overview

HKL-4291 GC for Trace Ethylene Glycol in Used Engine Oil conforms to ASTM D4291 Standard Test Method for Trace Ethylene Glycol in Used Engine Oil. It is used for the measurement of ethylene glycol as a contaminant in used engine oil. The ethylene glycol is supposed to be in the range from 5 to 200 mass ppm.

The sample of oil is extracted with water and the analysis is performed on the water extract. A reproducible volume of the extract is injected into a gas chromatograph using on-column injection and the eluting compounds are detected by a flame ionization detector. The ethylene glycol peak area is determined and compared with areas obtained from the injection of freshly prepared known standards.

Leakage of aqueous engine coolant into the crank case weakens the ability of the oil to lubricate. If ethylene glycol is present, it promotes varnish and deposit formation. This test method is designed for early detection to prevent coolant from accumulating and seriously damaging the engine.

Features

  1. A 5.7-inch large screen liquid crystal display with a 320×240 dot matrix resolution allows perfect real-time monitoring of the temperatures and operating conditions for each channel.

  2. Automatic startup self-test, six independent temperature control channels, and seven-stage program temperature rise function.

  3. Wide-range self-diagnosis function: Upon the occurrence of an instrument failure, it immediately displays the fault phenomenon, fault code, and fault cause, which enables you to rapidly find and fix problems and continue with optimal laboratory working condition.

  4. Over-temperature protection function: Allows arbitrary setting of protection temperatures. If any channel exceeds the set temperature, the instrument automatically cuts off power and alarms.

  5. Gas interruption and leakage protection function of carrier gas: The instrument will automatically stop the power and heating when the pressure of the carrier gas is too low, which makes the chromatographic column and thermal conductivity detector well protected from the damage.

  6. An intelligent fuzzy-logic-guided rear vent system is able to monitor temperature continuously and change the vent aperture by the amount necessary, so that accurate heat control is guaranteed at a very high level of precision even in situations close to ambient conditions.

  7. The system can handle several different ways of making injections, such as on-column injection for packed columns, glass liner injection, capillary split/splitless injection with septum purge, it is also being compatible with gas sampling accessories.

  8. Dual-path gas stabilization ensures exceptional flow precision, allowing concurrent operation of up to four detectors.

  9. The optimized flow architecture enables the simultaneous utilization of both a flame ionization detector (FID) and a thermal conductivity detector (TCD).

  10. Eight programmable external event channels facilitate sophisticated multi-valve switching and sequence control.

  11. Options include an electronic flow/pressure display module and an integrated workstation for enhanced operational convenience.

Technical Parameters

Temperature Parameters

  1. Temperature range: Ambient+5℃~ 400℃, Increment: 0.1℃

  2. Accuracy: ≤±0.1℃

  3. Programmed heating: Constant temperature time between five steps 0~999min, increment: 0.1min, temperature increment: 0.1℃

  4. Heating rate: max. 40℃/min below 200℃, max. 20℃/min above 200℃

Specification

  1. Dimension: 555mm*525mm*485mm

  2. Input power: AC220V±7%, 50Hz, 2Kw

  3. Net weight: About 52kg

Standard Calibration

Prepare glycol standards over the quantification range of 0.01% to 0.2% w/w in motor oil

Chromatogram

ASTM D4291

Chromatogram shows elution of ethylene glycol

GC

Calibration curve of ethylene glycol

FAQ

  1. Q1: What standards does this product (HKL-4291 GC for Trace Ethylene Glycol in Used Engine Oil) comply with?

    A:HKL-4291 GC for Trace Ethylene Glycol in Used Engine Oil conforms to ASTM D4291 Standard Test Method for Trace Ethylene Glycol in Used Engine Oil. It is used for the measurement of ethylene glycol as a contaminant in used engine oil. The ethylene glycol is supposed to be in the range from 5 to 200 mass ppm. The sample of oil is extracted with water and the analysis is performed on the water extract. A reproducible volume of the extract is injected into a gas chromatograph using on-column injection and the eluting compounds are detected by a flame ionization detector. The ethylene glycol peak area is determined and compared with areas obtained from the injection of freshly prepared known standards.

  2. Q2: Significance and use of HKL-4291 GC for Trace Ethylene Glycol in Used Engine Oil?

    A:Leakage of aqueous engine coolant into the crank case weakens the ability of the oil to lubricate. If ethylene glycol is present, it promotes varnish and deposit formation. This test method is designed for early detection to prevent coolant from accumulating and seriously damaging the engine.

  3. Q3: What is the minimum order quantity? How long is the delivery lead time?

    A: The minimum order quantity is one unit, and delivery is approximately 20 days after advance payment.

  4. Q4: Do you support online training services?

    A: For support, we are able to online install and commissioning of your equipment, provision of operational training in detail. Besides that we provide 24/7 online end user training support throughout the year.

  5. Q5: What international shipping options do you support?

    A: We provide various international shipping choices that are flexible enough to suit your requirements: (1) International Express: Partnering with the world’s top courier companies like DHL, FedEx, UPS, and TNT, this is a good option for small quantities and expensive items. (2) Air Freight: A perfect solution for medium-sized shipments and it is a quite good price-performance ratio. (3) Sea freight: Good for large orders that can fill entire containers or just part of them. Usually, it takes around 20-40 days for the goods to arrive depending on which port they are going to. (4) Rail freight: Mainly for customers who want to trade with the towns and countries on the Eurasian landmass like Central Asia, Russia or Europe. This brand provides reliable and efficient China-Europe Railway Express services.

Gas Chromatograph

About us

Established in 2018, Hong Kong Laboratory Technology Limited has rapidly risen to be one of the best suppliers of supply chain solutions for the scientific instrument industry. Having gained more than 8 years’experience in the profession, we have linked over 500 Research and Development customers to one of the largest supplier networks of over 50 leading manufacturers, thereby enabling a seamless transition from innovation to mass production. The main products since the first generation comply with the instrument calibration and testing standards of ISO/IEC 17025 and have also been sold to research institutions, petrochemical and mining industries, medical institutions, and environmental protection departments. This type of quality with a high standard has obtained a wide range of trust from the market and customers.

Company Advantages

(1)Full-Chain Resource Integration Capability

(2)Professional Technical Service Team

(3)Rich Industry Practical Cases

(4)Reliable After-Sales Service

Service Guarantee

1. Online Training Services

We are always willing to lend a helping hand. And if you require, we can do an online installation and commissioning, not forgetting extensive training that will make you ready to operate. What’s more to guarantee your team’s continuous performance, we provide 24/7 online training support, all year round.

2. Professional After-Sales Service

We offer tailored maintenance plans for different instrument types. Our goal is to be your preferred partner, recognized for delivering top quality and dependable instruments. Besides that, we constantly welcome your feedback that will enable us to improve our services and cater to your needs more effectively. Thanks for sharing this path with us.

Logistics and Shipping

Worldwide Shipping: We have very good logistics channels that cover Asia, Europe, Middle East and other parts of the world. That means we will be able to serve you with international shipping services that are both efficient and reliable.

Secure Packaging: Laboratory instruments are very tightly packed so that they are sufficiently secured and well protected going through the transit process.

International Certification

ASTM D4291 GC

ISO 9001 Certification

ASTM Certificate

1. HKL-4291 GC for Trace Ethylene Glycol in Used Engine Oil conforms to ASTM D4291 Standard Test Method for Trace Ethylene Glycol in Used Engine Oil. 2. It is used for the measurement of ethylene glycol as a contaminant in used engine oil. The ethylene glycol is supposed to be in the range from 5 to 200 mass ppm.

HKL

Hong Kong,China

deliver as soon as received payment

30 sets one month

Product Info

Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)