• ISO 12966 Gas Chromatograph Instrument for Fatty Acids
  • video

ISO 12966 Gas Chromatograph Instrument for Fatty Acids

  • HKL
  • Hong Kong,China
  • deliver as soon as received payment
  • 30 sets one month
1. The instrument is suitable for characterizing fats and oils, or fat-containing foods after lipid extraction from the matrix. 2. The fatty acid-specific gas chromatograph is applicable for analyzing all natural and synthetic mixtures of triglycerides, diglycerides, monoglycerides, as well as fatty acid esters, free fatty acids, saponified products, and other aliphatic compounds.

HKL-12966 Gas Chromatograph for Fatty Acids Analysis

Overview

The HKL-12966 Gas Chromatograph for Fatty Acids Analysis conforms to the ISO 12966 Animal and vegetable fats and oils — Gas chromatography of fatty acid methyl estersPart 4: Determination by capillary gas chromatography. The dissolved fatty acid methyl esters are injected into and vaporized within the injector. The separation of FAMEs is achieved on analytical columns of different polarities and lengths. For the detection of the FAMEs, a flame ionization detector is used.

Features

  1. Featuring a 5.7-inch LCD screen, the device combines intuitive physical controls with a user-centric interface.

  2. Made to be equivalent to international advanced rotary inlets with quick-change liners; it allows simpler and faster maintenance.

  3. The high-sensitivity FID hydrogen flame detectors that are produced according to the ones with top specifications worldwide are equipped, in addition, with an automatic ignition capability.

  4. The instrument incorporates a built-in workstation and USB interface, which allows connection to any computer system and configuration.

  5. Switching on, CPU self-test and self-diagnostic capabilities help fault detection to be fast and straightforward.

  6. Developed to deliver top performance, the large column oven of the instrument guarantees better analytical accuracy and great repeatability.

  7. The cool-down time is greatly shortened by a combination of a large-capacity column oven, a high-power fan, and a smart rear-exhaust automatic cooling system.

  8. The system features corrosion-resistant circuit components, a very high level of noise immunity, and over-temperature protection as one of the integral safeties.

  9. Using a programmable multi-valve assembly, the GC system can perform automatic, repeatable injection cycles with sophisticated temperature ramp and external event controls.

  10. Optional liquid autosampler for unattended automated injection.

  11. Overall dimensions: 610 × 515 × 520 mm.

Technical Parameters

  1. Inlet System indicators

    1)Inlet: Swing-top sealing system with rapid-disassemblymodularity.

    2)Maximum Operating Temperature: 400°C

    3)Number of Inlets: Supports up to 3 inlets

    4)Injection Modes: Packed column injection, Split capillary column injection, Valve injection

  2. Temperature Control Indicators

    1)Dimensions: 300 × 300 × 250 mm (L × W × D)

    2)Temperature Control Range: Ambient +5°C ~ 400°C, increment 0.1°C

    3)Temperature Setting Increment: 0.1°C

    4)Temperature Control Accuracy: ±0.1°C

    5)Programmed Temperature Ramp: 7 stages

    6)Heating Rate: 0 ~ 40°C/min, Inter-stage Hold Time: 0 ~ 999 min

    7)Cooling Performance (Ambient 19°C): ≤ 4 min (from 300°C to 100°C)

FAQ

  1. Q1: What standards does this product (HKL-12966 Gas Chromatograph for Fatty Acids Analysis) comply with?

    A:The HKL-12966 Gas Chromatograph for Fatty Acids Analysis conforms to the ISO 12966 Animal and vegetable fats and oils — Gas chromatography of fatty acid methyl esters Part 4: Determination by capillary gas chromatography. The dissolved fatty acid methyl esters are injected into and vaporized within the injector. The separation of FAMEs is achieved on analytical columns of different polarities and lengths. For the detection of the FAMEs, a flame ionization detector is used.

  2. Q2: What is the applicable scope of HKL-12966 Gas Chromatograph for Fatty Acids Analysis?

    A:This part of ISO 12966 specifies a method for the determination of fatty acid methyl esters (FAMEs) derived by transesterification or esterification from fats, oils, and fatty acids by capillary gas chromatography (GLC). Fatty acid methyl esters from C8 to C24 can be separated using this part of ISO 12966 including saturated fatty acid methyl esters, cis- and trans-monounsaturated fatty acid methyl esters, and cis- and trans-polyunsaturated fatty acid methyl esters. The method is applicable to crude, refined, partially hydrogenated, or fully hydrogenated fats, oils, and fatty acids derived from animal and vegetable sources. This method is not suitable for the analysis of dairy, ruminant fats and oils, or products supplemented with conjugated linoleic acid (CLA). Milk and milk products (or fat coming from milk and milk products)are excluded from the scope of this part of ISO 12966.

  3. Q3: What is the minimum order quantity? How long is the delivery lead time?

    A: The minimum order quantity is one unit, and delivery is approximately 20 days after advance payment.

  4. Q4: How can I get a product quotation?

    A: Please submit your requirements via the contact page on our official website or customer service email, and we will contact you within 24 hours with a detailed quotation.

  5. Q5: What international shipping methods do you support?

    A: There are several ways for you to ship your packages internationally with us:(1) International Express: Consulting with world-leading courier companies such as DHL, FedEx, UPS, and TNT, suitable for the delivery of small batches and high-value commodities(2) Air Freight: Perfect for delivering medium-sized shipments at a good price point.(3) Sea Freight: Basically, this is ideal for massive orders that are very large in volume. Through this service, FCL and LCL options are possible, while the delivery time is roughly 20-40 days depending on the location of the destination port.(4) Rail Freight: Mainly, the railroad freight service is aimed at customers in the Eurasian continent (for instance, Central Asia, Russia, Europe). The service is distinguished by long-term stable and efficient China-Europe Railway Express operations.

Fatty Acids Analyzer

About us

Hong Kong Laboratory Technology Limited (HKLT) established in 2018, is one of the leading supply chain solutions providers in the scientific instrument industry. Through our knowledge of over eight years in this field, we have linked more than 500 Research and Development clients with one of the largest supplier networks consisting of over 50 top manufacturers, thus enabling a smooth transition from innovation to mass production. Our operations are very well controlled by a robust quality management system and the main product lines not only meet the worldwide standards such as ISO 9001, ASTM, and IP but also comply with the very stringent requirements of the ISO/IEC 17025 calibration standard. This commitment to precision and quality has resulted in us being the most preferred partner of scientific research institutions, hospitals, environmental agencies, as well as the mining and petrochemical industries.

Company Advantages

(1)Full-Chain Resource Integration Capability

(2)Professional Technical Service Team

(3)Rich Industry Practical Cases

(4)Reliable After-Sales Service

Service Guarantee

1. Online Training Services

We are ready to assist you at any step. If you wish, we can carry out online installation, commissioning, and supply comprehensive training for you to start working quickly. Moreover, to secure your team’s continuous progress, we give you access to 24-hour online training support throughout the year.

2. Professional After-Sales Service

We have dedicated maintenance plans for various instrument types. Our goal is to be your ideal partner, recognized for offering the highest quality and most trustworthy instruments. We continuously encourage you to share your ideas and critiques so that together we can improve our services and tailor them to your requirements. We really appreciate your involvement in our joint effort.

Logistics and Shipping

Worldwide Shipping: Our logistics channels are well-established and cover Asia, Europe, the Middle East, and other parts of the world, so we can provide you with international shipping services that are both efficient and reliable.

Secure Packaging: Laboratory instruments are very carefully packed to ensure that they are properly secured and adequately protected against damages that might occur during transportation.

International Certification

Gas Chromatograph GC

ISO 9001 Certification

ASTM Certificate

1. The instrument is suitable for characterizing fats and oils, or fat-containing foods after lipid extraction from the matrix. 2. The fatty acid-specific gas chromatograph is applicable for analyzing all natural and synthetic mixtures of triglycerides, diglycerides, monoglycerides, as well as fatty acid esters, free fatty acids, saponified products, and other aliphatic compounds.

HKL

Hong Kong,China

deliver as soon as received payment

30 sets one month

Product Info

Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)