HKL-16000 Gas Chromatograph for Indoor Pollution Control
Overview
The HKL-16000 Gas Chromatograph for Indoor Pollution Control conforms to the ISO 16000-6 Indoor air —Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in indoor and test chamber air by active sampling on sorbent tubes, thermal desorption and gas chromatography using MS or MS FID. A certain amount of air sample is collected from the indoor air and drawn through one (or more) adsorbent tubes. The compounds retained by these adsorbent tubes are then analyzed. The compounds collected are heated to release them and then the compounds are moved to a gas chromatograph with capillary column to detection and analysis.
Features
Equipped with a 5.7 inch LCD display, ergonomically designed physical controls, and an intuitive user interface, we guarantee you a smooth operational interaction.
Adopts iThe use of internationally advanced rotary injection port technology combined with quick-change liners allows for fast and easy maintenance.
Features a Flame Ionization Detector (FID) of the highest sensitivity with automatic ignition, meeting world-class performance standards.
Built-in workstation software and a USB interface ensure universal compatibility with major computer operating systems and hardware configurations.
Includes power-on CPU self-test and diagnostic features, enabling quick and easy fault identification.
A large column oven improves analytical accuracy and repeatability.
A large-capacity column oven, high-efficiency fan, and intelligent rear-exhaust cooling system work together to increase cooling efficiency, supporting optimal workflow continuity.
Corrosion-resistant, durable circuit boards combined with anti-interference and over-temperature protection mechanisms ensure stable and reliable instrument performance.
Supports multi-stage temperature programming as well as external event control; the multi-valve switching system allows for timed and quantitative cyclic injection.
A liquid autosampler is optional, enabling fully automated, unattended sample processing.
Overall dimensions: 610 mm (W) × 515 mm (D) × 520 mm (H)
Technical Parameters
Inlet System indicators
1)Inlet: Swing-top sealing system with rapid-disassemblymodularity.
2)Maximum Operating Temperature: 400°C
3)Number of Inlets: Supports up to 3 inlets
4)Injection Modes: Packed column injection, Split capillary column injection, Valve injection
Temperature Control Indicators
1)Dimensions: 300 × 300 × 250 mm (L × W × D)
2)Temperature Control Range: Ambient +5°C ~ 400°C, increment 0.1°C
3)Temperature Setting Increment: 0.1°C
4)Temperature Control Accuracy: ±0.1°C
5)Programmed Temperature Ramp: 7 stages
6)Heating Rate: 0 ~ 40°C/min, Inter-stage Hold Time: 0 ~ 999 min
7)Cooling Performance (Ambient 19°C): ≤ 4 min (from 300°C to 100°C)
FAQ
Q1: What standards does this product (HKL-16000 Gas Chromatograph for Indoor Pollution Control) comply with?
A: The HKL-16000 Gas Chromatograph for Indoor Pollution Control conforms to the ISO 16000-6 Indoor air —Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in indoor and test chamber air by active sampling on sorbent tubes, thermal desorption and gas chromatography using MS or MS FID. A certain amount of air sample is collected from the indoor air and drawn through one (or more) adsorbent tubes. The collected compounds are first desorbed by heating. Then, these compounds are transferred to the gas chromatograph fitted with a capillary column for their detection and analysis.
Q2: What is the applicable scope of HKL-16000 Gas Chromatograph for Indoor Pollution Control?
A: This document specifies a method for determination of volatile organic compounds (VOC) in indoor air and in air sampled for the determination of the emission from products or materials used in indoor environments (according to ISO 16000-1) using test chambers and test cells. The method uses sorbent sampling tubes with subsequent thermal desorption (TD) and gas chromatographic (GC) analysis employing a capillary column and a mass spectrometric (MS) detector with or without an additional flame ionisation detector (FID). The method is applicable to the measurement of most GC-compatible vapour-phase organic compounds at concentrations ranging from micrograms per cubic metre to several milligrams per cubic metre. The choice of sorbents allows the analysis of a wide range of very volatile organic compounds (VVOC) and semi-volatile organic compounds (SVOC).
Q3: What is the minimum order quantity? How long is the delivery lead time?
A: The minimum order quantity is one unit, and delivery is approximately 20 days after advance payment.
Q4: How can I get a product quotation?
A: Please submit your requirements via the contact page on our official website or customer service email, and we will contact you within 24 hours with a detailed quotation.
Q5: What kind of after-sales service do you support?
A: We pledge to equip you with an extensive and dependable after-sales support scheme from the beginning to the end of the product’s lifetime. This encompasses:(1) Prompt Reaction: There will always be a skilled customer service department ready to help you so that you get time-efficient responses to your requirements.(2) Expert Technical Engineer Assistance: A knowledgeable group of engineers offers remote troubleshooting in order to swiftly deal with the technical problems. (3) Continuous Empowerment: Our service lasts beyond the initial product to provide you with online training and guidance for your team to thoroughly use the instrument’s capability. We don’t just solve problems, that is only the beginning. We want to be your laboratory partner whom you can trust. We will make sure that the instrument is stable and that the data are accurate and reliable, thus, you will be able to focus on your scientific research even better.

About us
Hong Kong Laboratory Technology Limited, which was set up in 2018, has quickly become a dependable supplier of supply chain solutions for the scientific instrument sector. With our professional experience of more than 8 years, we have connected over 500 Research and Development clients to an extensive supplier network of more than 50 leading manufacturers, facilitating a smooth pathway from innovation to mass production. With our deep understanding of the industry, the company develops top-notch management systems and complies with various international standards, such as ISO 9001, ASTM, and IP. Besides the strict observance of ISO/IEC 17025 requirements for the calibration and testing of instruments, our main products are very much recognized in different sectors, such as research institutions, petrochemical and mining industries, hospitals, and environmental protection agencies.
Company Advantages
(1)Full-Chain Resource Integration Capability
(2)Professional Technical Service Team
(3)Rich Industry Practical Cases
(4)Reliable After-Sales Service
Service Guarantee
1. Online Training Services
We are ready to support you at every step of your journey. Should you require it, we can equip you with online installation and commissioning sessions and comprehensive training for your readiness. Besides that, to maintain the success of your team in the long run, we provide online training support 24/7, all year round for 365 days.
2. Professional After-Sales Service
We offer targeted maintenance solutions for various instrument categories. Our goal is to become your preferred partner, recognized as a provider of top-quality and highly dependable instruments. We highly appreciate your feedback and recommendations as they are crucial for us to improve our services and serve you better. We are grateful that you joined us in this cooperative path.
Logistics and Shipping
Worldwide Shipping: We are very familiar with international logistics that we can guarantee the smooth delivery to Asia, Europe, and the Middle East destinations.
Secure Packaging: Laboratory instruments are carefully packed to ensure that they are properly secured and protected from any damage during transportation.
International Certification
|
|
ISO 9001 Certification | ASTM Certificate |